Customization: | Available |
---|---|
Container Size: | 1360*560*960mm |
Weight: | 440kg |
Still deciding? Get samples of US$ 2000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Built with off grid inverter charger
CAN / RS485 / WIFI APP
Multi working modes selectable
Modular design, flexible installation
INVERTER : HP 12048DR 48V / 12KW
BATTERY : LFP 48200R*3 51.2V / 200AH
MPPT : SCM 48240R 240A / 48V
SOLAR PANELS : 370M6H 370W*36PCS
Model | Configuration | |||
ESS12048E600P4 | MPPT-SCM 48240R | INVERTER-HP 12048DR | BATTERY-LFP 48200R*3 | Total energy |
240A(60A*4) | 12KW | 600AH(200AH*3) | 30.72kwh | |
Battery | Description | |||
Normal specification | ||||
1 | Rated Voltage | 51.2V | ||
2 | Rated Capacity | 600Ah | ||
3 | Rated Energy | 30.72KWH | ||
4 | Battery Configuration | 10.24KWH(16S2P) *3PCS | ||
5 | Battery Cell | 3.2V100AH 96PCS | ||
Standard Charge | ||||
1 | Operation temperature range @charging | 0~45ºC | ||
2 | Rated charge voltage | 55.2±0.4V | ||
3 | Max charge voltage | 56.8±0.4V | ||
4 | Overcharge protection | 58.4±0.4V | ||
5 | Allowed MAX charge current(Total) | 330A withstand 30s (every pack 110A) | ||
6 | Peak charge current(Total) | 360A withstand 5s (every pack 120A) | ||
7 | Rated charge current(Total) | 300A (every pack 100A) | ||
8 | Recommend charge current(Total) | <300A | ||
Standard discharge | ||||
1 | Operation temperature range @discharging | -20~60ºC | ||
2 | Output Voltage Range | 40~56Vdc | ||
3 | Recommend Working Range | 46~54Vdc | ||
4 | Discharge Cut-off voltage | 40V | ||
5 | Allowed MAX discharge current(Total) | 660A withstand 30s (every pack 220A) | ||
6 | Peak discharge current(Total) | 720A withstand 5s (every pack 240A) | ||
7 | Rated discharge current(Total) | 600A (every pack 200A) | ||
8 | Recommend discharge current(Total) | <600A | ||
Communication | ||||
1 | RS485 | For LCD remote | ||
2 | CAN | PC control and monitor | ||
Inverter (built-in) | Description | |||
Normal specification | ||||
1 | Rated Power | 12KW | ||
2 | Output Waveform | Pure Sine Wave/Same as input (Bypass Mode) | ||
3 | Output Voltage | 240Vac(H-H)/120Vac(H-N) ±10% RMS | ||
4 | Output Frequency | 50 or 60± 0.3Hz (Inverter mode by sw4 setting) | ||
5 | Typical Transfer Time | 4-6ms typical,10ms(Max) | ||
6 | THD | < 3%(Rated voltage full R load) | ||
7 | AC Input Range | 184-253Vac (UPS mode) or 140-270Vac (GEN mode) | ||
8 | Customized AC Charger | Battery type selector position 9, special design for LFP, make the battery cycle life Maximization | ||
9 | MAX AC Charge Current | 100A | ||
10 | Battery priority Function | Setting by SW5 on position 1 (inverter mode valid), AC automatic come in when battery voltage low alarm at 48Vdc or 50Vdc | ||
11 | AC Bypass without charging | Battery type selector position 0 | ||
MPPT (built-in) | Description | |||
Normal specification | ||||
1 | PV POWER | 3.5KW*4 | ||
2 | PV Input Voltage | 60-145Vdc | ||
3 | MPPT Charging Voltage | 56.0Vdc (Fast charging)/54Vdc (Float charging) | ||
4 | MPPT Output Current | 60A*4 | ||
Mechanical Characteristics | ||||
ESS12048E600P4 | Dimension H*W*D | Shipping H*W*D | Weight(N.W.) | Weight(G.W.) |
1360*560*960mm | 1540*700*1050mm | 440KG | 480KG |
we are manufacture of battery for more than 10years. We have 3 manufacture base in Shenzhen, Guangdong, Shaoguan. There are 2 automatic production lines in our Shenzhen Base. Our price is very competitve in the market on the condition of comparing to the same quality products.
Our technical manager is in lithium battery industry for more than 15years, and we have lots of experience for OEM & ODM.